medium | breathing air acc. | DIN 3188 / EN 12021 : 2014 |
intake pressure | bar abs. | 1-1,2 |
rated overpressure | max bar. | 350 |
delivered quantity measured at number of stages | 3 | |
number of cylinders | 3 | |
cylinder 1st stage | ø mm | 60 |
cylinder 2nd stage | 28 | |
cylinder 3rd stage | 12 | |
piston travel | mm | 24 |
intermediate overpressures | ||
1st stage approx. | bar | 5,5 - 6,5 |
2nd stage approx. | bar | 55 -65 |
Enddruck | bar | 225 und / or 330 |
rotating direction | counter clockwise | |
cooling | air | |
lubrication | splash lubrication with oil whizzer pin | |
quantity of lubricating oil | l | 0,36 |
oil type | Synthetic Oil | |
tolerated maximum ambient temperature | +5° bis +45° | |
tolerated maximum inclination | 10° | |
interval for condensate emptying | every 10-15 minutes |
DRIVE MOTOR
three-phase squirrel Cage motor (E3) | 3kW | 400 V, 50/60Hz |
mono-phase electric engine | 2,2kW | 230 V, 50/60Hz |
4 stroke petrol engine. | 4,2kW | manual start |
StandardEquipment:
- compressor and motor mounted on frame with shock absorbers. Frame, manufactured in light weight construction, is designed for easy change of power sources.
- Micronic – suction filter
- splash lubrication
- interstage coolers
- aftercooler
- manual condensate drain for draining the separators
- end pressure safety valve 225 bar or 330 bar
- pressure gauge
FILTER SYSTEM F 140
- COMP TRADE long-term filter cartridge for 3-stage air conditioning
- air quality DIN 3188 / EN 12021 : 2014
- filling : MS-AC-MS supplying air quality according to DIN 3188 / EN 12021 : 2014
- recyclable air volume ca. 140 m³ bei 20° environmental temperature
fill connection with filling unit 225 bar or 330 bar
- filling unit DIN connection G 5/8" for 200 or 300 bar, end pressure gauge and 1m filling hose with self-venting filling valve
Optional Equipment
ADDITIONAL FILLING CLOSURE consisting of:
- filling unit with DIN connector G 5/8" for 200 or 300 bar, end pressure gauge and 1m filling hose with self-venting filling valve
SECOND PRINTING AREA consisting of:
- filling unit with DIN connector G 5/8" for 200 bar, end pressure gauge and 1m filling hose with self-venting filling valve and safety valve 225 bar
AUTO-STOP
- pressure switch with cut-off when the final pressure is reached
AUTOMATIC DRAINAGE SYSTEM
- drains all separators between the individual stages and also the final separator during compressor Operation
- magnetic valvel
PRESEC INTEL
- a monitoring system for filter cartridge saturation and maintenance Level without external power supply and sensors, activated by the compressor operation itself.